VALID FIRE-INSPECTOR-II EXAM DISCOUNT | FIRE-INSPECTOR-II LATEST TEST SIMULATOR

Valid Fire-Inspector-II Exam Discount | Fire-Inspector-II Latest Test Simulator

Valid Fire-Inspector-II Exam Discount | Fire-Inspector-II Latest Test Simulator

Blog Article

Tags: Valid Fire-Inspector-II Exam Discount, Fire-Inspector-II Latest Test Simulator, Fire-Inspector-II Certification Test Answers, Valid Fire-Inspector-II Exam Question, Latest Fire-Inspector-II Exam Cost

BONUS!!! Download part of ITCertMagic Fire-Inspector-II dumps for free: https://drive.google.com/open?id=1byOfgn43zIjVamfAuuXCss-CmBjjIHaR

If you want to Fire-Inspector-II practice testing the product of ITCertMagic, feel free to try a free demo and overcome your doubts. A full refund offer according to terms and conditions is also available if you don't clear the 67 - Fire Inspector II Exam (Fire-Inspector-II) practice test after using the 67 - Fire Inspector II Exam (Fire-Inspector-II) exam product. Purchase ITCertMagic best Fire-Inspector-II study material today and get these stunning offers.

These International Code Council Fire-Inspector-II exam questions are modeled after the Fire-Inspector-II test. They will assist you in learning how to manage your time during the examination. ITCertMagic enabled all users to regulate time during their 67 - Fire Inspector II Exam Fire-Inspector-II test. And it can be accomplished via practice, as practice makes perfect. Therefore, you must practice passing the Fire-Inspector-II exam.

>> Valid Fire-Inspector-II Exam Discount <<

Fire-Inspector-II exam study guide

Dare to pursue, we will have a good future. Do you want to be successful people? Do you want to be IT talent? Do you want to pass International Code Council Fire-Inspector-II certification? ITCertMagic will provide you with high quality dumps. It includes real questions and answers, which is useful to the candidates. ITCertMagic International Code Council Fire-Inspector-II Exam Dumps is ordered, finished, and to the point. Only ITCertMagic can perfect to show its high quality, however, not every website has high quality exam dumps. Than cardiac operations a rush to purchase our International Code Council Fire-Inspector-II Oh! The successful rate is 100%.

International Code Council 67 - Fire Inspector II Exam Sample Questions (Q82-Q87):

NEW QUESTION # 82
Atmospheric tanks with hazardous materials shall be equipped with a liquid-level limit control if they have a capacity which is greater than __ gallons.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

Explanation:
Reference to Liquid-Level Limit Control Requirements for Atmospheric Tanks:
According to The International Fire Code (IFC 2021), Section 5704.2.7.5, atmospheric tanks containing hazardous materials must be equipped with a liquid-level limit control if their capacity exceeds 500 gallons.
This requirement ensures that overfilling is prevented, reducing the risk of hazardous spills, leaks, and fire hazards.
Purpose of Liquid-Level Limit Controls:
These controls automatically shut off or alert operators when the liquid level reaches a predetermined limit.
They prevent tank overfill and reduce the risk of hazardous material release, which can cause fires, explosions, or environmental contamination.
Clarification of Incorrect Answer Choices:
A: 55 gallons # Incorrect
55-gallon drums are not subject to the same overfill protection requirements as large atmospheric tanks.
B: 100 gallons # Incorrect
Too low based on IFC 5704.2.7.5, which sets the requirement at 500 gallons.
C: 250 gallons # Incorrect
Some local regulations may require monitoring for tanks of this size, but IFC specifies 500 gallons as the mandatory threshold.
Conclusion:
The correct and verified answer is D (500 gallons) based on IFC 5704.2.7.5, ensuring proper overfill protection for atmospheric tanks containing hazardous materials.


NEW QUESTION # 83
Refrigeration units or systems having a refrigerant circuit containing Group A1 refrigerant shall be provided with approved emergency signs, charts, and labels in accordance with NFPA 704 when the quantity exceeds
___ lb.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

Explanation:
Refrigeration systems and units are regulated under IFC 2021, Section 605 - Refrigeration Equipment, and the requirement for emergency signs, charts, and labels is tied to the NFPA 704 Hazardous Materials Identification System.
IFC 2021, Section 605.12.3 - Signage for Refrigeration Systems:
States that approved emergency signs, charts, and labels must be provided when the refrigerant quantity exceeds 220 pounds for Group A1 refrigerants.
Definition of Group A1 Refrigerants (Low Toxicity, Low Flammability):
Examples include R-134a, R-410A, and R-22, which are commonly used in commercial and industrial HVAC systems.
Why Other Options Are Incorrect?
A: 30 lb. - Too low; labeling requirements do not apply at this threshold.
B: 100 lb. - Incorrect; the IFC requirement specifies 220 lb.
C: 200 lb. - Close, but still below the 220 lb. threshold.


NEW QUESTION # 84
The use of listed portable unvented oil-burning heating appliances is prohibited in which of the following occupancies?

  • A. Groups R-3, M, S-1, and S-2 occupancies
  • B. Groups A, E, I, R-1, R-2, R-3, and R-4 occupancies
  • C. Groups A and B occupancies
  • D. Groups B and F occupancies

Answer: B

Explanation:
Restrictions on Portable Unvented Oil-Burning Heaters
According to the International Fire Code (IFC) 2021, Section 603.4, the use of listed portable unvented oil- burning heating appliances is prohibited in certain occupancies where fire and life safety risks are higher.
The prohibited occupancies include:
Group A (Assembly) - Includes theaters, churches, stadiums, etc.
Group E (Educational) - Includes schools, daycares, etc.
Group I (Institutional) - Includes hospitals, nursing homes, jails, etc.
Group R-1, R-2, R-3, R-4 (Residential Occupancies) - Includes hotels, apartments, assisted living, and residential care facilities.
2. Why These Occupancies Are Prohibited
Portable unvented oil-burning heaters pose a significant fire hazard and can produce harmful gases such as carbon monoxide.
In high-occupancy and residential buildings, improper use or malfunction of these heaters could lead to fatal fire or health hazards.
Ventilation concerns in institutional and assembly settings make these heaters particularly dangerous.
3. Verification of Other Options
Option A (Groups A and B occupancies) - Incorrect, as Group B (Business) is not explicitly prohibited from using these heaters.
Option B (Groups B and F occupancies) - Incorrect, as Group F (Factory/Industrial) is not listed under IFC
603.4 as a prohibited occupancy.
Option C (Groups R-3, M, S-1, and S-2 occupancies) - Incorrect, as M (Mercantile) and S (Storage) occupancies are not listed as restricted areas.
Reference Sources:
International Fire Code (IFC) 2021 - Section 603.4 (Portable Unvented Oil-Burning Heating Appliances) NFPA 1: Fire Code (Portable Heater Use Restrictions in Various Occupancies)


NEW QUESTION # 85
A building under construction which has two stairways shall have a minimum of how many fire extinguishers per floor?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: C

Explanation:
Reference to Fire Extinguisher Requirements in Buildings Under Construction:
NFPA 241 (Standard for Safeguarding Construction, Alteration, and Demolition Operations) Section 13.6.1 and IFC 3309.1 require that:
A minimum of one fire extinguisher per floor is required.
Additional extinguishers are required based on stairwells and floor area.
If a building under construction has two stairways, a minimum of two fire extinguishers must be provided per floor to ensure adequate fire protection coverage.
Fire Safety Considerations for Construction Sites:
Construction sites pose a high fire risk due to temporary electrical systems, combustible materials, and lack of finished fire suppression systems.
Fire extinguishers must be readily available and evenly distributed near exit stairways and pathways for rapid access in case of an emergency.
Clarification of Incorrect Answer Choices:
A: 1 # Incorrect
One extinguisher is the minimum required for floors with only one exit/stairway, but a building with two stairways requires at least two extinguishers.
C: 3 # Incorrect
While more extinguishers can be added for larger areas or high-risk work zones, the minimum requirement remains two for two stairwells.
D: 4 # Incorrect
There is no general requirement for four extinguishers per floor unless dictated by floor size and hazard level.
Conclusion:
The correct and verified answer is B (2 fire extinguishers per floor) based on NFPA 241 and IFC 3309.1, ensuring compliance with fire safety standards for buildings under construction.


NEW QUESTION # 86
Incineration operations must comply with which of the following requirements?

  • A. Incineration operations must stop if the fire code official determines that the odor is offensive to nearby residents
  • B. Operators must be at least 21 years of age
  • C. Fuel-fired incinerators must be preheated for at least 20 minutes before use
  • D. Incineration which creates an odor when burning requires a fire permit

Answer: A

Explanation:
IFC allows fire code officials to enforce odor control, requiring operations to stop if odors are offensive (D), aligning with public safety. Options A, B, and C are not standard requirements, with age limits (A) not specified, permits (B) not universally required for odors, and preheating time (C) not mandated. This fits the study guide's incineration regulations.
References: Fire Inspector II Study Guide, IFC.


NEW QUESTION # 87
......

If you feel that you always suffer from procrastination and cannot make full use of your spare time, maybe our Fire-Inspector-II study materials can help you solve your problem. We are willing to recommend you to try the Fire-Inspector-II learning guide from our company. Our products are high quality and efficiency test tools for all people with three versions which satisfy all your needs. If you buy our Fire-Inspector-II Preparation questions, you can use our Fire-Inspector-II practice engine for study in anytime and anywhere.

Fire-Inspector-II Latest Test Simulator: https://www.itcertmagic.com/International-Code-Council/real-Fire-Inspector-II-exam-prep-dumps.html

International Code Council Valid Fire-Inspector-II Exam Discount So they totally trust us, All these three Fire-Inspector-II real dumps formats contain the actual and updated Fire-Inspector-II 67 - Fire Inspector II Exam exam questions that will surely repeat in the upcoming Fire-Inspector-II exam and you can easily pass it with good scores, While when you get our email and download Fire-Inspector-II Latest Test Simulator - 67 - Fire Inspector II Exam vce test engine on your PC or some other electronic device, you may doubt it is safety or not, International Code Council Valid Fire-Inspector-II Exam Discount Extra service for one year.

Click the Next buttons accepting the default for the following Fire-Inspector-II Latest Test Simulator dialogs in the wizard, Network security vendors are challenged to create products that protect networks from existing external and internal threats, defend against Fire-Inspector-II new and emerging hacking methods, and be easy for network administrators to manage and not cost an arm and a leg.

Fire-Inspector-II Real Test Practice Materials - Fire-Inspector-II Study Guide - ITCertMagic

So they totally trust us, All these three Fire-Inspector-II real dumps formats contain the actual and updated Fire-Inspector-II 67 - Fire Inspector II Exam exam questions that will surely repeat in the upcoming Fire-Inspector-II exam and you can easily pass it with good scores.

While when you get our email and download 67 - Fire Inspector II Exam vce test Valid Fire-Inspector-II Exam Question engine on your PC or some other electronic device, you may doubt it is safety or not, Extra service for one year.

We also provide you good service: 7*24 on-line Fire-Inspector-II Certification Test Answers service: no matter when you contact with us we will reply you at the first time.

DOWNLOAD the newest ITCertMagic Fire-Inspector-II PDF dumps from Cloud Storage for free: https://drive.google.com/open?id=1byOfgn43zIjVamfAuuXCss-CmBjjIHaR

Report this page